Guhindura Porotokole

  • ODOT-PNM02 V2.0 / V2.1: Modbus-RTU / ASCll cyangwa protocole idasanzwe kuri ProfiNet Converter

    ODOT-PNM02 V2.0 / V2.1: Modbus-RTU / ASCll cyangwa protocole idasanzwe kuri ProfiNet Converter

    ODOT-PNM02 V2.1

    Modbus (umutware / imbata, RTU / ASCII) kugeza kuri ProfiNET, icyambu 2 cyicyambu (RS485 / RS232 / RS422), gishyigikira ibibanza 50, amategeko 200 muri TIA

    portal (na software yagenwe), shyigikira imbata MAX 60

    Gushyigikira protocole ihinduka hagati ya Modbus na PROFINET

    Shyigikira 2 * RS485 / RS232 cyangwa 1 * RS422

    Ashigikira Modbus umutware cyangwa imbata, kandi ashyigikira RTU cyangwa ASCII

    Gushyigikira ubushyuhe bwakazi bwa -40〜85 ° C.

    Gushyigikira amakuru yamakuru: 2 serial Modbus-RTU / ASCII kumarembo ya PROFIBUS hamwe na Max.kwinjiza 1440 bytes na Max.ibisohoka 1440 bytes

    Gushyigikira gusubiramo urufunguzo rumwe

    ♦ ODOT-PNM02 V2.0 ishyigikira ahantu ntarengwa: 50

    ♦ ODOT-PNM02 V2.1 ishyigikira imbata 60 (200 soma kandi wandike amategeko)

  • ODOT-S4E2: 4 Serial Modbus RTU / ASCII kuri Modbus TCP ihindura

    ODOT-S4E2: 4 Serial Modbus RTU / ASCII kuri Modbus TCP ihindura

    Gushyigikira protocole ihinduka hagati ya Modbus-RTU na Modbus-TCP

    Gushyigikira guhuza abakiriya 5 TCP icyarimwe

    ♦ ODOT-S2E2 ishyigikira 2 * RS485

    ♦ ODOT-S4E2 ishyigikira insinga za RS485 / RS232 / RS422

    ♦ Buri cyambu gikurikirana gishyigikira Modbus masterand imbata

    ♦ ODOT-S2E2: 2 serial Modbus-RTU / ASCII kugeza Modbus-TCP Irembo rya Serveri

    ♦ ODOT-S4E2: 4 serial Modbus-RTU / ASCII kugeza Modbus-TCP Irembo rya Serveri

    Gushyigikira gusubiramo urufunguzo rumwe

    Mode Uburyo bwo gukora amarembo: Gukwirakwiza mu mucyo, ikarita ya aderesi

  • ODOT-S2E2: 2 Serial Modbus RTU / ASCII kugeza Modbus TCP Guhindura

    ODOT-S2E2: 2 Serial Modbus RTU / ASCII kugeza Modbus TCP Guhindura

    Gushyigikira protocole ihinduka hagati ya Modbus-RTU na Modbus-TCP

    Gushyigikira guhuza abakiriya 5 TCP icyarimwe

    ♦ ODOT-S2E2 ishyigikira 2 * RS485

    ♦ ODOT-S4E2 ishyigikira insinga za RS485 / RS232 / RS422

    ♦ Buri cyambu gikurikirana gishyigikira Modbus masterand imbata

    ♦ ODOT-S2E2: 2 serial Modbus-RTU / ASCII kugeza Modbus-TCP Irembo rya Serveri

    ♦ ODOT-S4E2: 4 serial Modbus-RTU / ASCII kugeza Modbus-TCP Irembo rya Serveri

    Gushyigikira gusubiramo urufunguzo rumwe

    Mode Uburyo bwo gukora amarembo: Gukwirakwiza mu mucyo, ikarita ya aderesi

  • ODOT-DPM01: Modbus-RTU kuri Profibus-DP Guhindura

    ODOT-DPM01: Modbus-RTU kuri Profibus-DP Guhindura

    Gushyigikira protocole ihinduka hagati ya Modbus na PROFIBUS

    Gushyigikira RS485, RS422 na 232

    Ashigikira Modbus umutware n'umugaragu, kandi ashyigikira RTU cyangwa ASCII

    Gushyigikira ibidukikije bikora -40 ~ 85 ° C.

    PROFIBUS-DP: Mak.Ongeramo 244 bytes, Byinshi.Ibisohoka 244 bytes

    ♦ DPM01: 1-inzira Modbus kugeza PROFIBUS irembo ryumucakara, igiteranyo cyinjiza nibisohoka ni 288 bytes.

    DPM02:

  • MG-CANEX CANopen kuri Modbus TCP ihindura

    MG-CANEX CANopen kuri Modbus TCP ihindura

    MG-CANEX Porotokole Ihindura

    CANopen kuri Modbus TCP protocole ihindura

    MG-CANEX ni protocole ihindura kuva CANopen kuri Modbus TCP.Igikoresho gikina nka shobuja murusobe rwa CANopen kandi rushobora guhuzwa nibikoresho bisanzwe bya CANopen.Kohereza amakuru ashyigikira PDO, SDO, no kugenzura amakosa ashyigikira Umutima.Bishyigikira ubutumwa bwoherejwe kandi butajyanye no kohereza.

    Nka seriveri ya TCP mumurongo wa Modbus TCP, igikoresho gishobora kugerwaho nabakiriya 5 ba TCP icyarimwe, kandi gishobora guhuzwa numugenzuzi wa PLC nubwoko butandukanye bwa software.Irashobora kandi guhuza optique ya transceiver no kumenya kohereza intera ndende.

  • ODOT-S1E1 V2.0: Irembo ryuruhererekane

    ODOT-S1E1 V2.0: Irembo ryuruhererekane

    Numuhinduzi wateguwe na Sichuan Odot Automation Sisitemu Co, LTD hagati ya RS232 / 485/422 na TCP / UDP.Iyi protocole ihindura irashobora guhuza byoroshye ibikoresho byicyambu cya seriveri na Ethernet kandi ikamenya kuzamura imiyoboro yibikoresho byicyambu.

    Guhindura protocole ishyigikira imikorere ya "data data", ishobora gushyirwaho nkumukiriya cyangwa seriveri.Iyi mikorere irashobora kumenya byoroshye itumanaho ryamakuru hagati ya PLC, seriveri nibindi bikoresho bya Ethernet hamwe nibikoresho byuruhererekane.

    Shyigikira seriveri ya TCP hamwe nabakiriya ba TCP mucyo
    Shyigikira UDP mucyo no kohereza ibyambu
    Shyigikira ihererekanyabubasha hamwe cyangwa nta protocole.Porotokole ikwirakwizwa mu mucyo ishyigikira MODBUS RTU / ASCII
    Shyigikira ibipimo bya mushakisha ya WEB (Ibipimo bisanzwe) Serial port baud igipimo cya 1200 kugeza 115200 bps

  • ODOT-S7MPIV2.0: Imigaragarire ya PPI / MPI / PROFIBUS kuri EtherNet

    ODOT-S7MPIV2.0: Imigaragarire ya PPI / MPI / PROFIBUS kuri EtherNet

    Yashyizwe ku cyambu cy'itumanaho cya PPI / MPI / PROFIBUS ya PLC, muri rusange nta mbaraga zituruka hanze

    Shyigikira Siemens S7 Abashoferi b'itumanaho rya Ethernet, harimo MicroWIN, STEP7, Port ya TIA, WinCC nibindi.

    ♦ Byahujwe na Modbus-TCP seriveri, agace ka Modbus karashobora guhita cyangwa guhindurwa kugirango ikarita yandike S7-200 / 300/400

    Connection S7TCP ihuza hamwe na Modbus-TCP itumanaho rishobora kugerwaho icyarimwe

    ♦ Kugera kuri 32 byakira mudasobwa ihuza

    ♦ MPI kuri S7 Ethernet / Modbus-TCP ihindura

    Gushyigikira gusubiramo urufunguzo rumwe